...
- The Total GHG field should not be sent at all.
- User should not be able to send any values for all emission values and emission method types.(should be nulls)
if it is a Fuel
- The GHG method type field shouldn't be sent at all.
- The Total GHG field should not be sent at all.
- User should not be able to send any values for all emission values and emission method types.(should be nulls)
3.DDV :
if it is a Raw Material
- The Total GHG field should not be sent at all.
- At least one of the POS data fields indicating the emission method type should have a value of "DDV".
- Emission values provided without selecting the "DDV" emission method type option will not be accepted.
- GHG Reductions (ESCA, ECCS,ECCR) - The reduction fields should not allow any values to be entered. (Greyed out in UI).
- Fields indicating the emission method type should include only the value DDV.
- The EL field value can be positive, zero or negative (for all methods).
- The land use change type value must be specified for the given EL field value, except when it is zero.
if it is a Fuel
- The GHG method type field shouldn't be sent at all.
- The Total GHG field should not be sent at all.
- The only Emission value allowed is the ETD value.
4.DDV_AV :
if it is a Raw Material
- The Total GHG field should not be sent at all.
- At least one DDV and one AV method type are required( one of the POS data fields indicating the emission method type should have a value of "DDV" and one of them should have a value of "AV" ).
- The "AV" option should not be sent without a specified emission value.
- Emission values provided without selecting the "DDV" or "AV" types will not be accepted.
- GHG Reductions(ESCA,ECCS,ECCR) - Only positive values are accepted.
- The EL field value can be positive, zero or negative (for all methods).
- The land use change type value must be specified for the given EL field value, except when it is zero.
if it is a Fuel
- The GHG method type field shouldn't be sent at all.
- The Total GHG field should not be sent at all.
- The only Emission value allowed is the ETD value.
5.AV :
if it is a Raw Material
- The Total GHG field should not be sent at all.
- The "AV" option should not be sent without a specified value (At least one Emission field is required) and it must be a positive value or zero.
- The EL field value can be positive, zero or negative (for all methods).
- The land use change type value must be specified for the given EL field value, except when it is zero.
if it is a Fuel
- The GHG method type field shouldn't be sent at all.
- The Total GHG field should not be sent at all.
- The only Emission value allowed is the ETD value.
6. NUTS2 : not applicable to the Part B, Seller Transaction
...