E delivery services Impacted :


EOUpdatePOSRequest 

EOAddPoOTradeRequest (Part B) -->the Raw Material only

EOAddFGPTransactionRequest (Part A)-->the Raw Material only

                                                  (POO Stock)

EOAddTransactionRequest (Seller Transaction)

EOInternalTransfer


1.The Total GHG value calculated in UDB ,based on provided data, is  the sum of  the E fields values across all methods.


2.TDV : 

      if it is a Raw Material

  • The Total GHG field should not be sent.
  • User should not be able to send any values for all emission values and emission method types.(should be nulls)
  •  The GHG method type field should be sent.

      if it is a Fuel

  • The Total GHG field should not be sent.
  • User should not be able to send any values for all emission values and emission method types.(should be nulls)
  •  The GHG method type field should not be sent.


3.DDV :

 if it is a Raw Material

  • The Total GHG field should not be sent.
  • At least one of the POS data fields indicating the emission method type should have a value of "DDV".
  • Emission values provided without selecting the "DDV"  emission method type option  will not be accepted.
  • GHG Reductions (ESCA, ECCS,ECCR) - The reduction fields should not allow any values to be entered. (Greyed out in UI).
  • Fields indicating the emission method type should include only the value DDV.
  • The EL field value can be positive, zero or negative (for all methods).
  • The land use change type value must be specified for the given EL field value, except when it is zero.

if it is a Fuel

    •  The GHG method type field should not be sent.
    • The Total GHG field should not be sent.
    • The only Emission value allowed is the ETD value.


4.DDV_AV :

 if it is a Raw Material

  • The Total GHG field should not be sent.
  • At least one DDV and one AV method type are required( one of the POS data fields indicating the emission method type should have a value of "DDV" and  one of them should have a value of "AV" ).
  • The "AV" option should not be sent without a specified emission value.
  • Emission values provided without selecting the "DDV" or "AV" emission type will not be accepted.
  • GHG Reductions(ESCA,ECCS,ECCR) - Only positive values are accepted.
  • The EL field value can be positive, zero or negative (for all methods).
  • The land use change type value must be specified for the given EL field value, except when it is zero.

if it is a Fuel

  •  The GHG method type field shouldn't be sent.
  • The Total GHG field should not be sent.
  • The only Emission value allowed is the ETD value.
  • The "DDV" or "AV" emission type shouldn't' be sent for the  ETD_AV_DDV field.



5.AV :

if it is a Raw Material

  • The Total GHG field should not be sent.
  • The "AV" option should not be sent without a specified value (At least one Emission field is required) and it must be a positive value or zero.
  • The EL field value can be positive, zero or negative (for all methods).
  • The land use change type value must be specified for the given EL field value, except when it is zero.

if it is a Fuel

  •  The GHG method type field shouldn't be sent.
  • The Total GHG field should not be sent.
  • The only Emission value allowed is the ETD value.


6. NUTS2 : not applicable to the Part B, Seller Transaction 

  • The Total GHG field should not be sent.
  • Material list is restricted. Only NUTS2 materials  are accepted.
  • NUTS2 region field is mandatory.
  • All other field tags under the NUTS2 region field need to be removed.
  • Do not provide any emission field value and any emission method type when using NUTS2.


7.DDV_NUTS2 : not applicable to the Part B, Seller Transaction

  • The Total GHG field should not be sent.
  • Material list is restricted.  Only NUTS2 materials  are accepted.
  • NUTS2 region field is mandatory.
  • At least one of the POS data fields indicating the emission method type should have a value of "DDV".
  • For EEC (NUTS2  value), do not allow the emission method type to have a value of "DDV".
  • Emission values provided without selecting the "DDV"  emission method type option  will not be accepted.
  • GHG Reductions (ESCA, ECCS,ECCR) - The reduction fields should not allow any values to be entered. (Greyed out in UI).
  • The EL field value can be positive, zero or negative (for all methods).
  • The land use change type value must be specified for the given EL field value, except when it is zero.