Every time an EO performs a transaction for feedstocks or intermediate products ,it is his responsibility to indicate their portion of the emissions in gC02 eq/DMT.
Until the point of fuel producer, these emissions will be accumulated in the UDB across the value chain, based on the emissions added by each EO for their respective activities.
The fuel producer should calculate emissions in gCO2eq/MJ using the metadata available for the consignment and encode the values once when utilizing the material processing feature.
The transactions GHG possible method type combinations
Input Material GHG method type | Possible GHG method type modification |
---|---|
TDV | TDV |
DDV | DDV |
DDV_AV | DDV_AV |
AV | AV,DDV_AV |
DDV_NUTS2 | DDV_AV |
NUTS2 | AV,DDV_AV |
AV,DDV_AV | DDV_AV |
AV,NUTS2 | AV,DDV_AV |
AV,DDV_NUTS2 | DDV_AV |
DDV_AV,NUTS2 | DDV_AV |
DDV_AV,DDV_NUTS2 | DDV_AV |
NUTS2,DDV_NUTS2 | DDV_AV |
AV,DDV_AV,NUTS2 | DDV_AV |
AV,DDV_AV,DDV_NUTS2 | DDV_AV |
DDV_AV,NUTS2,DDV_NUTS2 | DDV_AV |
DDV_AV,AV,DDV_NUTS2,NUTS2 | DDV_AV |
PART B POINT OF ORIGIN BUYER TRADE - RAW MATERIALS (The default unit for fuel greenhouse gas (GHG) emissions is kgCO2eq/DMT.)
Method Type | EEC | EL | EP | ETD | ESCA | ECCS | ECCR | Total | Comments | ||||
TDV | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out with no value | The Total GHG field is greyed out and set to null. | ||||
DDV | Enabled: DDV | Not enabled (Greyed out) | Enabled: DDV | Enabled: DDV | Greyed out | Greyed out | Greyed out | Greyed out with no value | The Total GHG field is greyed out and set to null. Please make sure at least one dropdown selection is set to 'DDV'. | ||||
DDV_AV | Enabled: either DDV or AV along with its given value. | Enabled: AV along with its given value. The value may be negative. The land use field must be provided if "EL" value is entered except when "EL" is set to 0. | Enabled: either DDV or AV along with its given value. | Enabled: either DDV or AV along with its given value. | Enabled:given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled:given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled:given value will be considered as AV value (reductions for DDV not allowed by default) | Greyed out with the total of the given values | Please ensure that at least one dropdown selection is set to 'DDV' and another to 'AV' . The EL value will be treated as 'AV' by default ,so there's no need to add an additional 'AV' option in the dropdown. Values are only accepted if the 'AV' option is selected from the dropdown. | ||||
AV | Enabled | Enabled The value may be negative. The land use field must be provided if "EL" value is entered except when "EL" is set to 0. | Enabled | Enabled | Enabled | Enabled | Enabled | Greyed out with the total of the given values | At least one E field is required. |
PART A AND FOOD & FEED CROPS POINT OF ORIGIN BUYER TRADE ,POINT OF ORIGIN STOCK REGISTRATION and INITIAL STOCK REGISTRATION - RAW MATERIALS (The default unit for fuel greenhouse gas (GHG) emissions is kgCO2eq/DMT.)
Method Type | EEC | EL | EP | ETD | ESCA | ECCS | ECCR | Total |
Comments |
TDV | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out with no value | The Total GHG field is greyed out and set to null. |
DDV | Enabled: DDV | Not enabled (Greyed out) | Enabled: DDV | Enabled: DDV | Greyed out | Greyed out | Greyed out | Greyed out with no value | The Total GHG field is greyed out and set to null. Please make sure at least one dropdown selection is set to 'DDV'. |
DDV_AV | Enabled: either DDV or AV along with its given value. | Enabled: AV along with its given value. The value may be negative. The land use field must be provided if "EL" value is entered except when "EL" is set to 0. | Enabled: either DDV or AV along with its given value. | Enabled: either DDV or AV along with its given value. | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Greyed out with the total of the given values | Please ensure that at least one dropdown selection is set to 'DDV' and another to 'AV' . The EL value will be treated as 'AV' by default ,so there's no need to add an additional 'AV' option in the dropdown. Values are only accepted if the 'AV' option is selected from the dropdown. |
AV | Enabled | Enabled The value may be negative. The land use field must be provided if "EL" value is entered except when "EL" is set to 0. | Enabled | Enabled | Enabled | Enabled | Enabled | Greyed out with the total of the given values | At least one E field is required.
|
NUTS2 | The EEC emission field value is fetched from the NUTS2 table and is not editable. | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out with the "EEC" Value | The Total GHG value is always greater than 0. |
DDV_NUTS2 | The EEC emission field value is fetched from the NUTS2 table and is not editable. | Not enabled (Greyed out) | Enabled: DDV | Enabled: DDV | Greyed out | Greyed out | Greyed out | Greyed out with the "EEC" Value | The Total GHG value is always greater than 0. Please make sure at least one dropdown selection is set to 'DDV'. |
SELLER TRANSACTION ( including Internal transfer)
OR
Raw Material (The default unit for fuel greenhouse gas (GHG) emissions is kgCO2eq/DMT.)
Method Type | Seller ETD | Buyer ETD |
Comments |
TDV | Greyed out | Greyed out The option 'Accept without saving the E details' is available. | Only the transportation distance fields are available for entry. |
DDV | Mandatory: DDV(Greyed out) | Mandatory: DDV (Greyed out) The option 'Accept without saving the E details' is available. | The DDV option is mandatory The transportation distance fields are available for entry. |
DDV_AV (the possible input consignments include DDV_AV,AV,NUTS2,DDV_NUTS2 types.) | Enabled: either DDV or AV along with its given value. 1.if the transaction consignments are of different types (DDV_AV,AV,NUTS2,DDV_NUTS2 types) and the consignments ETD field is of a different type (DDV,AV) then the only available the GHG method type is DDV_AV and the transaction ETD value will be added to the consignment ETD based on the provided type : if the consignment ETD field type is "AV" then the ETD value will be updated to the selected type (AV/DDV), if the consignment ETD field type is "DDV" it will remain unchanged. 2.if the transaction consignments are of different types (AV,NUTS2 types) and the selected ETD field is of type AV ,the GHG method type is automatically assigned a value of type AV. 3.If one or all of the transaction consignments are of type DDV_NUTS2, the ETD field is automatically assigned a value of type DDV . | Enabled: either DDV or AV along with its given value. The seller's rules are applied to the Buyer choice as well. The option 'Accept without saving the E details' is available. | Please ensure that the dropdown selection is set to 'DDV' or 'AV' . Values are only accepted if the 'AV' option is selected from the dropdown. The transportation distance fields are available for entry. |
AV (the possible input consignments include AV,NUTS2 types.) | Enabled | Enabled The option 'Accept without saving the E details' is available. | The value is required for a Seller . The transportation distance fields are available for entry. |
Fuel (The default unit for fuel greenhouse gas (GHG) emissions is gCO₂eq/MJ.)
Method Type | Seller ETD | Buyer ETD | Comments |
TDV | Greyed out | Greyed out. The option 'Accept without saving the E details' is available. | Only the transportation distance fields are available for entry. |
DDV | Greyed out | Greyed out. The option 'Accept without saving the E details' is available. | Only the transportation distance fields are available for entry. |
DDV_AV (the possible input consignments include DDV_AV,AV types.) | Enabled and optional, if the transaction consignments ETD field is of a different type (DDV,AV) , the given value will be added to the consignment ETD based on the provided type :if "AV" then the ETD value will be updated, if "DDV" it will remain unchanged. Not enabled if the transaction consignments ETD field is of type DDV only. | Enabled and optional, if the transaction consignments ETD field is of a different type (DDV,AV) , the given value will be added to the consignment ETD based on the provided type :if "AV" then the ETD value will be updated, if "DDV" it will remain unchanged. Not enabled if the transaction consignments ETD field is of type DDV only. The option 'Accept without saving the E details' is available. | the added ETD emission (optionally) for a fuel will be considered as an actual value and added only to fuels with the actual ETD emission . The transportation distance fields are available for entry. |
AV | Enabled and optional | Enabled and optional | the ETD emission can be added (optionally) for a fuel. |
Material processing (Conversion)
Raw material-to-Intermediate Product/Raw material (The default unit for fuel greenhouse gas (GHG) emissions is kgCO2eq/DMT.): it should be recalculated according to the certification methodology.
Method Type | EEC | EL | EP | ETD | ESCA | ECCS | ECCR | Total |
Comments |
TDV | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out with no value | The Total GHG field is greyed out and set to null. |
DDV Existing values from the input material are copied into the relevant GHG fields. | Enabled and optional: DDV | Not enabled (Greyed out) | Enabled and mandatory (will be): DDV | Enabled and optional: DDV | Greyed out | Greyed out | Greyed out | Greyed out with no value | The Total GHG field is greyed out and set to null. |
DDV_AV Existing values from the input material are copied into the relevant GHG fields. (DDV_AV or DDV_NUTS2) | Enabled and optional: either DDV or AV along with its given value. The NUTS2 EEC is labeled as AV. | Enabled and optional: given value will be considered as AV value. | Enabled and mandatory (will be) : either DDV or AV along with its given value. | Enabled and optional: either DDV or AV along with its given value. | Enabled and optional: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled and optional: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled and optional: given value will be considered as AV value (reductions for DDV not allowed by default) | Greyed out with the given value | Please ensure that at least one dropdown selection is set to 'DDV' and another to 'AV' . Values are only accepted if the 'AV' option is selected from the dropdown. If the previous value is AV, it can be modified to DDV, but not vice versa. |
AV Existing values from the input material are copied into the relevant GHG fields. (AV or NUTS2) | Enabled and optional The NUTS2 EEC is labeled as AV. | Enabled and optional | Enabled and mandatory | Enabled and optional | Enabled and optional | Enabled and optional | Enabled and optional | Greyed out with the given value | The modified values should be equal to or greater than the previous values. |
Raw material-to-Fuel (The default unit for fuel greenhouse gas (GHG) emissions is gCO₂eq/MJ.) :it should be recalculated according to the certification methodology.
Output Method Type based on the Input product method | EEC | EL | EP | ETD | EU | ESCA | ECCS | ECCR | Total |
Comments |
TDV (TDV) | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out with the Annex V respective value for the fuel from Annex V/or enabled with the specified value Enabled for the fuels not defined in Annex V Total GHG field is mandatory |
|
DDV (DDV) | Enabled Enabled for the fuels not defined in Annex V | Greyed out | Enabled and mandatory Enabled for the fuels not defined in Annex V | Enabled and mandatory Enabled for the fuels not defined in Annex V | Greyed out ( for sustainable fuels the value is set to 0.) | Greyed out | Greyed out | Greyed out | Greyed out with the summarized value |
|
DDV_AV (DDV_AV or DDV_NUTS2) | Enabled: either DDV with a given or specified value, or AV with a specified value | Enabled (regarded as the actual value) | Enabled and mandatory: either DDV with a given or specified value, or AV with a specified value | Enabled and mandatory: either DDV with a given or specified value, or AV with a specified value | Greyed out ( for sustainable fuels the value is set to 0.) | Enabled (regarded as the actual value) | Enabled (regarded as the actual value) | Enabled (regarded as the actual value) | Greyed out with the summarized value |
|
AV (AV or NUTS2) | Enabled | Enabled | Enabled and mandatory | Enabled and mandatory | Greyed out ( for sustainable fuels the value is set to 0.) | Enabled | Enabled | Enabled | Greyed out with the summarized value |
The GHG method type update for the RM- to-RM combination conversion
Input Material GHG method type | Corresponding Output Material GHG method type | Possible GHG method type modification |
---|---|---|
TDV | TDV | TDV |
DDV | DDV | DDV,TDV |
DDV_AV | DDV_AV | DDV_AV,DDV,TDV |
AV | AV | AV,DDV_AV,DDV,TDV |
DDV_NUTS2 | DDV_AV | DDV_AV,DDV,TDV |
NUTS2 | AV | AV,DDV_AV,DDV,TDV |
The GHG method type update for the RM- to-Fuel combination conversion
Input Material GHG method type | Corresponding Output Material GHG method type | Possible GHG method type modification |
---|---|---|
TDV | TDV | TDV |
DDV | DDV | DDV,TDV |
DDV_AV | DDV_AV | DDV_AV,DDV,TDV |
AV | AV | AV,DDV_AV,DDV,TDV |
DDV_NUTS2 | DDV_AV | DDV_AV,DDV,TDV |
NUTS2 | AV | AV,DDV_AV,DDV,TDV |
E delivery conversion rules:
Method Type | Emissions EEC, EL, EP, EP, ETD, EU | Reductions ESCA, ECCS, ECCR | Total GHG for the Raw Material | Total GHG for the Fuel |
The RM Comments |
The Fuel Comments |
TDV | Emissions should not be set. | Reductions should not be set. | The GHG Total value should not be set. | 1.The GHG Total value must exceed zero. 2.if the fuel is defined in Annex V ,the provided total GHG value should match to Annex V. |
|
|
DDV | The only expected emissions fields are EEC,EP and ETD. | Reductions should not be set. | The GHG Total value should not be set. | 1. The GHG Total value is the cumulative sum of the DDV values . 2.if the fuel is defined in Annex V ,the provided values should match to Annex V. 3.The GHG Total value must exceed zero.
| Only the drop-down fields (EEC_DDV_AV,EP_DDV_AV,ETD_DDV_AV) should be sent with the DDV value. | Do not accept numeric values unless the matching DDV drop-down field value is provided.(for example: EEC=10 and ECC_DDV_AV=DDV) The sum of the emissions numeric values should match the Total GHG value. |
DDV_AV | Enabled: either DDV or AV options for EEC,EP and ETD fields. EL is AV by default. | Enabled: ESCA, ECCS, ECCR values will be considered as AV value by default. | 1.The GHG Total value is the cumulative sum of the AV values . 2.The GHG Total value must exceed zero. | 1.The GHG Total value is the cumulative sum of the AV_DDV values . 2.The GHG Total value must exceed zero. | At least one of drop-down values field (EEC_DDV_AV,EP_DDV_AV,ETD_DDV_AV) should be with the DDV or AV value. Not to accept numeric values provided without choosing the AV value. The provided AV values must match or exceed the input material’s values. The EP field is enabled and mandatory: either DDV or AV with a specified value. | At least one of drop-down values field (EEC_DDV_AV,EP_DDV_AV,ETD_DDV_AV) should be with the DDV or AV value. Not to accept numeric values provided without choosing the DDV or AV value. The EP and ETD fields are enabled and mandatory: either DDV with a specified value or AV with a specified value. |
AV | There are no restrictions for the emissions fields | There are no restrictions for the reductions. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | The EP field is enabled and mandatory with a specified value. The provided values must match or exceed the input material’s values. | The EP and ETD fields are enabled and mandatory with a specified value. |
DDV_NUTS2 can be converted to the DDV_AV,DDV,TDV methods. | The EEC field value (retrieved from the NUTS2_DEFINITION table during consignment creation) considered as AV value. | Reductions should not be set. | 1.The GHG Total value must exceed zero. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission fields. | The provided EEC value must match or exceed the input material’s value. | |
NUTS2 can be converted to the AV,DDV_AV,DDV,TDV methods. | The EEC field value (retrieved from the NUTS2_DEFINITION table during consignment creation) considered as AV value. |
| 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | The provided EEC value must match or exceed the input material’s value. |