PART B POINT OF ORIGIN BUYER TRADE - RAW MATERIALS (The default unit for fuel greenhouse gas (GHG) emissions is kgCO2eq/DMT.)
Method Type | EEC | EL | EP | ETD | EU | ESCA | ECCS | ECCR | Total | Comments | |||||
TDV | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Total GHG is greyed out and null. | |||||
DDV | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value. The value could be negative. The land use field should be provided if EL value is provided. | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Greyed out | Greyed out | Greyed out | Greyed out with or without given value | Total GHG can be null. At least one of drop-down values should be with the DDV value. Not to accept values provided without choosing the drop-down DDV | |||||
DDV_AV | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value. The value could be negative. The land use field should be provided if EL value is provided. | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Greyed out with given value | At least one of drop-down values should be with the DDV or AV value. Not to accept values provided without choosing the drop-down DDV or AV | |||||
AV | Enabled | Enabled. The value could be negative. The land use field should be provided if EL value is provided. | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Greyed out with given value | At least one E field is required. |
PART A AND FOOD & FEED CROPS POINT OF ORIGIN BUYER TRADE - RAW MATERIALS (The default unit for fuel greenhouse gas (GHG) emissions is kgCO2eq/DMT.)
Method Type | EEC | EL | EP | ETD | EU | ESCA | ECCS | ECCR | Total |
Comments |
TDV | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Total GHG is greyed out (null) |
DDV | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value. The value could be negative. The land use field should be provided if EL value is provided. | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Greyed out | Greyed out | Greyed out | Greyed out with given value | Total GHG can be null. At least one of drop-down values should be with the DDV value. Not to accept values provided without choosing the drop-down DDV |
DDV_AV | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value. The value could be negative. The land use field should be provided if EL value is provided. | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Greyed out with given value | At least one of drop-down values should be with the DDV or AV value. Not to accept values provided without choosing the drop-down DDV or AV |
AV | Enabled | Enabled. The value could be negative. The land use field should be provided if EL value is provided. | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Greyed out with given value | At least one E field is required.
|
NUTS2 | Only Emissions EEC field value fetching from NUTS2_DEFINITION Table | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out with EEC Value | Total GHG always greater than 0 |
DDV_NUTS2 | Only Emissions EEC field value fetching from NUTS2_DEFINITION Table | Enabled: either DDV or DDV and given value. The value could be negative. The land use field should be provided if EL value is provided. | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Greyed out | Greyed out | Greyed out | Greyed out with given value | Total GHG always greater than 0 At least one of drop-down values should be with the DDV value. Not to accept values provided without choosing the drop-down DDV. |
SELLER TRANSACTION
OR
Raw Material (The default unit for fuel greenhouse gas (GHG) emissions is kgCO2eq/DMT.)
Method Type | EEC | EL | EP | ETD | EU | ESCA | ECCS | ECCR | Total |
Comments |
TDV | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | The total fuel GHG value is null. |
DDV | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Greyed out | Greyed out | Greyed out | Greyed out with or without given value | Total GHG can be null. At least one of drop-down values should be with the DDV value. Not to accept values provided without choosing the drop-down DDV |
DDV_AV | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Greyed out with given value | At least one of drop-down values should be with the DDV or AV value. Not to accept values provided without choosing the drop-down DDV or AV |
AV | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Greyed out with given value | At least one E field value is required. |
Fuel (The default unit for fuel greenhouse gas (GHG) emissions is gCO₂eq/MJ.)
Method Type | EEC | EL | EP | ETD | EU | ESCA | ECCS | ECCR | Total | Comments |
TDV | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | We don’t display the total fuel GHG value at the POS screen. |
DDV | Greyed out | Greyed out | Greyed out | Enabled: given value | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out with or without given value | Only the ETD emission can be added (not mandatory) for a Fuel. |
DDV_AV | Greyed out | Greyed out | Greyed out | Enabled: given value | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out with given value | Only the ETD emission can be added (not mandatory) for a Fuel. |
AV | Greyed out | Greyed out | Greyed out | Enabled: given value | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out with given value | Only the ETD emission can be added (not mandatory) for a Fuel. |
CONVERSION (Material processing)
Raw material-to-Raw material
Method Type | EEC | EL | EP | ETD | EU | ESCA | ECCS | ECCR | Total |
Comments |
TDV | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Not modifiable |
DDV to copy existing values from the input material | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Greyed out | Greyed out | Greyed out | Greyed out with given value | Total GHG can be null. At least one of drop-down values should be with the DDV value. Not to accept values provided without choosing the drop-down DDV. |
DDV_AV to copy existing values from the input material | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Greyed out with given value | At least one of drop-down values should be with the DDV or AV value. Not to accept values provided without choosing the drop-down DDV or AV. |
AV to copy existing values from the input material | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Greyed out with given value | At least one E field is required. |
DDV_NUTS2 to copy existing values from the input material | Only Emissions EEC field value fetching from NUTS2_DEFINITION Table | Enabled: either DDV or DDV and given value. The value could be negative. The land use field should be provided if EL value is provided. | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Enabled: either DDV or DDV and given value | Greyed out | Greyed out | Greyed out | Greyed out with given value | Total GHG always greater than 0 At least one of drop-down values should be with the DDV value. Not to accept values provided without choosing the drop-down DDV. |
Raw material-to-Fuel:
Method Type | EEC | EL | EP | ETD | EU | ESCA | ECCS | ECCR | Total |
Comments |
TDV | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Greyed out | Enabled | Complete the POS by entering any number in Total Total GHG field is mandatory
Not modifiable |
DDV (to copy existing values from the input material) | Enabled | Enabled | Enabled | Enabled | Enabled | Greyed out | Greyed out | Greyed out | Greyed out with or without given value | Able to Complete the POS without giving any values.
At least one of drop-down values should be with the DDV value. Not to accept values provided without choosing the drop-down DDV. Total GHG can be zero. |
DDV_AV (to copy existing values from the input material) | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled: either DDV or DDV and given value or AV and given value | Enabled | Enabled | Enabled | Greyed out with given value | Able to Complete the POS without giving any values.
At least one of drop-down values should be with the DDV or AV value. Not to accept values provided without choosing the drop-down DDV or AV. To apply a check: “Total GHG should be greater than 0” |
AV to copy existing values from the input material | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Enabled | Greyed out with given value |
Able to Complete the POS without giving any values.
To apply a check: “Total GHG should be greater than 0” |
DDV_NUTS2 to copy existing values from the input material | Enabled: either DDV or NUTS2 and given value or NUTS2 and given value | Enabled | Enabled | Enabled | Enabled | Greyed | Greyed | Greyed | Greyed out with given value | Able to Complete the POS without giving any values.
total GHG always greater than 0 To add drop down lists. At least one of drop-down values should be with the DDV value. Not to accept values provided without choosing the drop-down DDV – to implement |
The GHG method type update for the RM- to-RM combination conversion
Input Material GHG method type | Corresponding Output Material GHG method type | Possible GHG method type modification |
---|---|---|
TDV | TDV | TDV |
DDV | DDV | DDV |
DDV_AV | DDV_AV | DDV_AV,DDV |
AV | AV | AV,DDV_AV,DDV |
DDV_NUTS2 | DDV_AV | DDV_AV,DDV |
NUTS2 | AV | AV,DDV_AV,DDV |
The GHG method type update for the RM- to-Fuel combination conversion
Input Material GHG method type | Corresponding Output Material GHG method type | Possible GHG method type modification |
---|---|---|
TDV | TDV | TDV |
DDV | DDV | DDV,TDV |
DDV_AV | DDV_AV | DDV_AV,DDV,TDV |
AV | AV | AV,DDV_AV,DDV,TDV |
DDV_NUTS2 | DDV_AV | DDV_AV,DDV,TDV |
NUTS2 | AV | AV,DDV_AV,DDV,TDV |
E delivery conversion rules:
Method Type | Emissions EEC, EL, EP, EP, ETD, EU | Reductions ESCA, ECCS, ECCR | Total GHG for the Raw Material | Total GHG for the Fuel |
The RM Comments |
The Fuel Comments |
TDV | Emissions should not be set. | Reductions should not be set. | The GHG Total value should not be set. | The GHG Total value must exceed zero. |
|
|
DDV | There are no restrictions for the emissions fields; their total should align with the GHG Total value. | Reductions should not be set. | The GHG Total value is the cumulative sum of the DDV values. | 1. The GHG Total value is the cumulative sum of the DDV values.2. The GHG Total value must exceed zero.
| Do not accept values unless the matching DDV drop-down value is provided. The total GHG can be zero if and only if at least one of the drop-down values matches the DDV value. | Do not accept values unless the matching DDV drop-down value is provided. |
DDV_AV | Enabled: either DDV or DDV and given value or AV and given value | Enabled: given value will be considered as AV value (reductions for DDV not allowed by default) | Greyed out with given value | Greyed out with given value | At least one of drop-down values should be with the DDV or AV value. Not to accept values provided without choosing the drop-down DDV or AV. To apply a check: “Total GHG should be greater than 0” | At least one of drop-down values should be with the DDV or AV value. Not to accept values provided without choosing the drop-down DDV or AV. To apply a check: “Total GHG should be greater than 0” |
AV | There are no restrictions for the emissions fields | There are no restrictions for thereductions. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | To apply checks: 1 The GHG Total value must exceed zero.2.the GHG Total value should match the sum of all Emission and Reduction fields. Do not accept values unless the matching AV drop-down value is provided. | To apply checks: 1. The GHG Total value must exceed zero.2.the GHG Total value should match the sum of all Emission and Reduction fields. Do not accept values unless the matching AV drop-down value is provided. |
DDV_NUTS2 | the Raw Material case: EEC field value fetching from NUTS2_DEFINITION Table | Reductions should not be set. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | To apply checks: 1. The GHG Total value must exceed zero.2.the GHG Total value should match the sum of all Emission and Reduction fields. 3.the original Pos of consignment should have DDV_NUTS2 or NUTS2 Do not accept values unless the matching DDV drop-down value is provided. To check the Nuts2 material and matching country. | NA |
NUTS2 | the Raw Material case: EEC field value fetching from NUTS2_DEFINITION Table | Reductions should not be set. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | 1.The GHG Total value must exceed zero. 2.the GHG Total value should match the sum of all Emission and Reduction fields. | To apply checks: 1. The GHG Total value must exceed zero.2.the GHG Total value should match the sum of all Emission and Reduction fields. 3.the original Pos of consignment should have DDV_NUTS2 or NUTS2 Do not accept values unless the matching DDV drop-down value is provided. To check the Nuts2 material and matching country. | NA |